Bwx-360A Accelerometer Automatic Test System for Inertial Testing

Model NO.: BWX-360A Accelerometer Automatic Test System
Working Range: -360°~ + 360° Continuous
Angular Resolution: 0. 0001° (0.36")
Angular Error: ±3"(Max. ±1" Can Be Achieved)
Angle Measuring Element: Imported Round Grating Encoder
Model NO.: BWX-360A Accelerometer Automatic Test System
Working Range: -360°~ + 360° Continuous
Angular Resolution: 0. 0001° (0.36")
Angular Error: ±3"(Max. ±1" Can Be Achieved)
Angle Measuring Element: Imported Round Grating Encoder
BWX-360A Accelerometer Automatic Test System
Main Technical Parameter
The performance of precision automatic indexing device
  1. Working range: -360°~ + 360° Continuous;
  2. Angular resolution: 0. 0001° (0.36");
  3. Angular error: ±3"(max. ±1" can be achieved);
  4. Axial load capacity: 10Kg (can be design and modification according requirement);
  5. Degree control mode: Automatic;
  6. Angular display mode: Digital display;
  7. Angle measuring element: Imported round grating encoder.
Temperature box performance indicators
  1. Temperature range: -70°C~+150°C;
  2. Temperature departure: ±2°C;
  3. Temperature fluctuation: 0.5°C;
  4. Temperature uniformity: 2°C;
  5. Temperature display mode: Digital display.
Horizontal position measurement system
  1. Measurement range: ±100";
  2. Measurement error: ±1";
  3. Display mode: Digital display.
Accelerometer data processing
The general model coefficient algorithm is based on GJB1 0 37a-2 0 04, and the special model coefficient algorithm is based on technical specification of the user's accelerometer.
Supervisor mode
The whole system is managed by the industrial control computer, and the system uses Windows 2000 environment. The control number software can achieve multi-task, menu style, Chinese display, and user-friendly operation.
BWX-360A Accelerometer Automatic Test System
Main Technical Parameter
The performance of precision automatic indexing device
  1. Working range: -360°~ + 360° Continuous;
  2. Angular resolution: 0. 0001° (0.36");
  3. Angular error: ±3"(max. ±1" can be achieved);
  4. Axial load capacity: 10Kg (can be design and modification according requirement);
  5. Degree control mode: Automatic;
  6. Angular display mode: Digital display;
  7. Angle measuring element: Imported round grating encoder.
Temperature box performance indicators
  1. Temperature range: -70°C~+150°C;
  2. Temperature departure: ±2°C;
  3. Temperature fluctuation: 0.5°C;
  4. Temperature uniformity: 2°C;
  5. Temperature display mode: Digital display.
Horizontal position measurement system
  1. Measurement range: ±100";
  2. Measurement error: ±1";
  3. Display mode: Digital display.
Accelerometer data processing
The general model coefficient algorithm is based on GJB1 0 37a-2 0 04, and the special model coefficient algorithm is based on technical specification of the user's accelerometer.
Supervisor mode
The whole system is managed by the industrial control computer, and the system uses Windows 2000 environment. The control number software can achieve multi-task, menu style, Chinese display, and user-friendly operation.

Flowmeter

Plastic Flowmeter is a widely used instrument in water treatment engineering, mainly used for flow detection, usually installed after the water pump, to control the water intake of each structure, currently the most widely used are electromagnetic flowmeter and ultrasonic flowmeter. In the selection of the flowmeter, the first thing to consider is the corrosiveness of the measured medium to the flow-passing parts, so as to avoid affecting the service life of the flowmeter due to the corrosion of the medium; During the design and installation process of the flowmeter, the length of the straight pipes before and after the flowmeter needs to be considered. Usually, the principle of 5D before and 3D after the flowmeter is followed. Here, D is the inner diameter of the pipe. If the length is insufficient, the measurement accuracy will be affected. When using an ultrasonic flowmeter, the distance between the first 10D and the rear 5D must be met, and the distance from the flowmeter to the water pump must be more than 30D.

When selecting the type, the flow rate of the medium in the pipeline needs to be between the maximum value and the minimum value of the selected flowmeter, and avoid approaching the maximum or minimum value, so as to avoid affecting the measurement accuracy.

Plastic Flowmeter,Acrylic Flowmeter,Solenoid Valve,Liquid Filled pressure gauge