Water Temperature Control Unit
Product Description
Brief introduction
KEWH series water heaters have both standard and high temperature models, which are used to heat up the mould and maintain temperature, although they can be used in other similar applications. High temperature water from the mould is returned to the cooling tank and cooled by either indirect cooling (For high temperature and high temperature plus pressure models) or direct cooling (For standard models). It is then pressurised by the high-pressure pump, sent to the heating tank and finally to the mould with a constant temperature. The KASSEL temperature controller can maintain an accuracy of ±1°C.
Standard Equipment
1. LCD Display, Choice of Language,
2. Siemens control parts,
3. Electric Cabinet Separation design
4. Over temperature Trip.
5. Return Temperature Display
6. Auto Ventilation
7. Safety Valve,
Water Temperature Control Unit,Water TCU,Water Temperature Control Units (TCU),Water Circulating Temperature Control Units Kassel Machinery (zhejiang) Co., Ltd. , https://www.kassel-group.com
1. Molybdenum-containing stainless steel (0Cr18Ni12Mo2Ti): It can withstand nitric acid, less than 5% sulfuric acid at room temperature, boiling phosphoric acid, formic acid, alkali solution, sulfurous acid under certain pressure, seawater, and acetic acid.
2, Hastelloy C (HC) / Hastelloy B (HB): oxidation-resistant acids, oxidizing salts, seawater, non-oxidizing acids, non-oxidizing salts, alkali, sulfuric acid at room temperature.
3, titanium (Ti): resistant to seawater, various chloride and hypochlorous acid, chlorinated acid (including fuming nitric acid), organic acids, alkali.
4. Ta (Ta): resistant to hydrofluoric acid, fuming sulfuric acid, other chemical media other than alkali, including boiling point hydrochloric acid, nitric acid and sulfuric acid less than 175 °C.
5, platinum (PT): resistant to various acids, alkalis, salts, does not include aqua regia.
Electromagnetic flowmeter electrode corrosion resistance
Electromagnetic flowmeters are primarily used to measure the volumetric flow in electrically conductive liquids and slurries in closed conduits. Including acid, alkali, salt and other corrosive liquids. The electromagnetic flowmeter and the media in contact with the site, in addition to the lining, there is the electrode, the correct and reasonable choice of electromagnetic flowmeter measuring electrode to extend the life of the electromagnetic flowmeter is of great significance. The following is a brief introduction of the electromagnetic flowmeter electrode performance for your reference.